SYNOVEX
® H
Fort Dodge
HEIFER IMPLANTS
For Increased Rate of Weight Gain and Improved Feed Efficiency
NADA 11-427, Approved by FDA
Each dosage consists of 8 pellets containing 200 mg testosterone propionate and 20 mg estradiol benzoate per implantation. This product was manufactured by a non-sterilizing process.
Synovex H Heifer Implants contain two pure steroid hormones, testosterone propionate and estradiol benzoate. This formulation provides a complementary amount of each hormone for maximal growth stimulation. Study the enclosed instructions carefully and use this product only as illustrated.
Important: Read ALL sides of carton
For Heifers Only
Do Not Use In Veal Calves
Not For Use In Humans
For Animal Use Only
For subcutaneous ear implantation only.
HOW TO IMPLANT WITH SYNOVEX® PELLETS
Study the following instructions carefully, then proceed step by step, until the technique becomes routine. Many head can be implanted per hour by an experienced team, one member of which should be assigned to do nothing but the implantation. This person should maintain hand cleanliness and use sanitary instruments only.
SYNOVEX® H Implants
Synovex H is recommended for use in heifers weighing 400 lbs or more.
When properly administered, Synovex H implants increase rate of weight gain and improve feed efficiency. Do not use in veal calves. Effectiveness and animal safety in veal calves have not been established.
Store at controlled room temperature 15° to 30°C (59° to 86°F). Avoid excessive heat or humidity.
DIRECTIONS: Implant complete contents of one cartridge cell per heifer. Approved implantation technique is fully described in the package insert.
NOTE: Never sacrifice careful, clean technique for speed of implantation.
WARNING
Not for use in humans. For animal use only. Not for dairy or beef replacement heifers. Implant pellets in the ear only. Any other location is in violation of federal law. Do not attempt salvage of implanted site for human or animal food.
A withdrawal period has not been established for this product in pre-ruminating calves. Do not use in calves to be processed for veal.
CAUTION
Bulling, vaginal and rectal prolapse, udder development, ventral edema and elevated tailheads have been occasionally reported in heifers administered with Synovex H implants.
Keep this and all drugs out of the reach of children.
Restricted Drug (California) - Use Only as Directed.
STEP 1 Loading The SYNOVEX Gun
Load the Synovex gun following the directions outlined in the instruction manual accompanying each Synovex gun.
STEP 2 Restraint
The animal must be confined in a restraint mechanism (squeeze chute or head gate). The implant site on the back of the ear should be prepared by scrubbing with a generous-sized piece of cotton that has been soaked in a germicidal solution.
Note: If implanting horned cattle, greater safety is provided when the head is controlled by the use of a bull lead (nose tongs).
STEP 3 Implant Site
Divide the ear into three imaginary sections as illustrated. The implanted pellets should be deposited in the center one-third of the ear as shown. To accomplish this, the Synovex gun needle should be inserted in the outer one-third of the ear as indicated by the "X" in the illustration. Implanting too close to the head may cause abnormal sexual behavior. Care should be taken to avoid severing the major arteries of the ear.
STEP 4 Insert Needle
Grasp the ear with one hand. Holding the Synovex gun firmly with the other hand, penetrate the skin at the point shown by the "X". Thrust the needle under the skin taking care not to penetrate the cartilage. Ease the Synovex gun forward (toward the base of the ear) until the full needle length is beneath the skin.
STEP 5 Pellet Implantation
When the needle is completely inserted, withdraw the needle approximately one-half inch. Then with continuous gentle pressure on the trigger, expel the pellets while continuing to slowly withdraw the needle. This technique allows the pellets to be deposited in a straight line in the path of the needle.
STEP 6 Inspection
Check the implant site. If properly administered, the implants should lie in a straight line under the skin.
Disinfect the Synovex gun needle in a germicidal solution. You are now ready to implant the next animal.
STEP 1 Loading The SX10 Gun
Load the SX10 gun following the directions outlined in the instruction manual accompanying each SX10 gun.
STEP 2 Restraint
The animal must be confined in a restraint mechanism (squeeze chute or head gate). The implant site on the back of the ear should be prepared by scrubbing with a generous-sized piece of cotton that has been soaked in a germicidal solution.
Note: If implanting horned cattle, greater safety is provided when the head is controlled by the use of a bull lead (nose tongs).
STEP 3 Implant Site
Divide the ear into three imaginary sections as illustrated. The implanted pellets should be deposited in the center one-third of the ear as shown. To accomplish this, the SX10 gun needle should be inserted in the outer one-third of the ear as indicated by the "X" in the illustration. Implanting too close to the head may cause abnormal sexual behavior. Care should be taken to avoid severing the major arteries of the ear.
STEP 4 Insert Needle
Just before grasping the ear with one hand, release the safety by striking the butt of the gun. Holding the SX10 gun firmly with the other hand, penetrate the skin at the point shown by the "X". Thrust the needle under the skin taking care not to penetrate the cartilage. Ease the SX10 gun forward (toward the base of the ear) until the full needle length is beneath the skin.
STEP 5 Pellet Implantation
When the needle is completely inserted, activate the instrument by squeezing the trigger completely. Do not withdraw the needle, but allow the automatic needle retractor to release the pellets. This will allow the pellets to be deposited in a straight line in the path of the retracted needle.
STEP 6 Inspection
Check the implant site. If properly administered, the implants should lie in a straight line under the skin.
Disinfect the SX10 gun needle in a germicidal solution and recock the instrument by rotating the cocking grip left, pull back, rotate right, then push all the way forward. You are now ready to implant the next animal.
HOW SUPPLIED
NDC 0856-3901-40 - 10 cartridges (100 Dose)
Each Cartridge Contains 10 Rows of 8 Pellets.
2004 Fort Dodge Animal Health. All Rights Reserved.
Fort Dodge Animal Health, Fort Dodge, Iowa 50501 USA
02474
6042F
NAC No.: 10032152